TH2819 Precision LCR Meter





Features:
  • 320×240 dot-matrix large graphics LCD display
  • Frequency up to 200 kHz with 10 mHz resolution
  • Basic accuracy: 0.05%
  • 2 different signal source output impedances: 30 Ω and 100 Ω
  • Open, Short and Load correction functions
  • List sweep function
  • Built-in comparator; 10 bins and bin counters.
  • Test signal level monitor function
  • Automatic level control function for V and I
  • 0 V, 1.5 V and 2 V internal DC bias voltage
  • Capable to operate with TH1773/TH1775 external DC bias current source
  • Optional ±10 V( ±100 mA) and 1A internal DC bias source
  • 20 control setting files can be saved in the internal non-volatile memory
  • Standard RS-232C interface Optional HANDLER, GPIB interface

Brief Introduce
:
TH2819 is a precision LCR meter with high accuracy, wide measurement range and six digit resolutions. TH2819 is used for incoming inspection of components, quality control of product line and laboratory use over a wide range of frequency (20 Hz to 200 kHz, 0.01 Hz resolution) and test signal level (5 mV to 2 V). The HANDLER, GPIB, RS-232C interfaces make it easy to build an automatic component test system, communicate with the computer and record the test results.

Specifications:
Test Parameter
|Z|, |Y|, C, L, X, B, R, G, D, Q, θ
Test Frequency 20 Hz to 200 kHz, Resolution: 0.01 Hz, Accuracy: 0.01%
Test Level
Range: 5 mV to 2 V, ALC Range: 10 mV to 1 V, Resolution: 1 mV, Accuracy: 5%
Output Impedance 30 Ω and 100 Ω selectable
Basic Accuracy 0.05%
Display Range |Z|, R, X 0.00001 O — 99.9999 MΩ
|Y|, G, B 0.00001 µS — 99.9999 S
C 0.00001 pF — 9.99999 F
L 0.00001 µH — 99.9999 kH
D 0.00001 — 9.99999
Q 0.00001 — 99999.9
θ(DEG) -179.999° — 179.999°
θ(RAD) -3.14159 — 3.14159
Δ%: -999.999% — 999.999%
Measuring Time (=1 kHz) Fast: 32 ms, Med: 90 ms, Slow: 650 ms
Equivalent Circuit Series and Parallel
Ranging Mode Auto and Hold
Trigger Mode Internal, Manual, External and Bus
Averaging Rate 1 — 255
Correction Function Open , Short and Load
Internal DC bias source 0 V, 1.5 V and 2 V, Accuracy: 1%
Comparator function 10 bins and bin counters
Memory 20 groups of control settings can be saved

General Specifications:

Operation Temperature And Humidity 0°C to 40°C, less than 90% RH
Power Requirements 198 V to 242 V AC, 47.5 Hz to 52.5 Hz
Power Consumption 80 VA max.
Dimensions(W×H×D) 430 mm×185 mm×473 mm
Weight 13 kg Approx

Ordering Information:
TH2819 Precision LCR Meter

Instrument Accessories:
TH26005-1 4 terminal test fixture
TH26011 4 terminal Kelvin test clip leads
TH26010 Gilded Shorting plate

Options
:

TH26001 4 terminal test fixture
TH26006 Axial lead component test module (used with TH26005)
TH26007 Core inductor test fixture
TH26008 SMD component test fixture
TH26009 SMD Kelvin test tweezers
TH26012 4 terminal Kelvin test clip leads
TH26016 HANDLER/Scanner cotrol cable
TH26017 USB interface control cable
TH26025 USB interface Board
TH26026 32 MB USB-Disk
TH26033 GPIB interface cable
TH26034 RS-232C interface cable
TH1802A 100 mA/10 V DC bias board
TH1802B 1 A DC bias board
TH10002 GPIB interface board
TH10202 HANDLER/Scanner interface board
TH11002 GPIB control software
TH12002 RS-232C control software